FEATURES
Stopwatch
Ø
Able
to measure 9 hours, 59 minutes, and 59.99 seconds in 1/100 second
Split
Time/Lap Measurement
Ø
Up
to 10 split time and lap time can be measured
Ø
Memory alert on last 5 available memory
Two Line Display
Ø
Total
elapse time, split time or lap time are displayed at the same time in
separate rows
Dual
Timer with Cycle Counter
Ø
2
count down timer each count up to 9 hour 59 minutes 59 seconds can be
operated consecutively for a maximum of 99 cycles
Stroke
(Frequency Counter)
Ø
Calculate
stroke frequency from 11 to 180 per minute
I. BATTERY
INSTALLATION
Ø
Remove
the back cover and the battery mounting by using a screwdriver
Ø
Install
the battery with the positive (+) pole facing the back cover
Ø
Replace the battery mounting and back cover
Ø
Should
the LCD show irregular figures, take out the battery and install again
II.
DISPLAY FORMAT IN DIFFERENT MODE
Press
button D to switch to different modes
Ø
Calendar Clock ®
(Press D) ®
Daily Alarm ®
(Press D) ®
Lap ®
(Press
D) ®
Split ®
(Press D) ®
Dual Timer ®
(Press D)
®
Stroke ®
(Press D) ®
Back to Calendar Clock
III.
CALENDAR AND CLOCK SETTING
Ø
Press button D to enter Calendar
& Clock mode.
Ø
Hold button C until seconds
digits are flashing to enter clock setting mode.
Ø
Press button B to adjust the
flashing digits and the press button A to confirm.
Ø
Right after the confirmation,
minutes digits will then start to flicker. Press button B again to adjust
and button A to confirm.
Ø
Repeat the above process until
you get a correct time setting.
Ø
As soon as time setting is
finished a “12H” display will be shown. Press button B to switch to 12
hour or 24 hour format and then press button C to confirm.
IV. ALARM SETTING MODE
Ø
Press
button D to enter Alarm mode.
Ø
Hold
button C until the hour digits are flashing to enter alarm setting mode.
Ø
Press
button B to adjust the flashing digits and then press button A to confirm.
Ø
Right
after the confirmation, minutes digits will then start to flicker. Press
button B again to adjust and button C to confirm.
V. ALARM ON/OFF
Ø
Press button D to enter Alarm mode
Ø
Press
button A to set alarm on
·)))
or off
VI. POWER SAVING
Ø
To
preserve batteries, the unit will automatically switch off if the unit is
left unused for over 9 hours.
Ø
Display
will reappear with a press on either buttons.
VII.
TROUBLESHOOTING
Malfunction
Problem
Incorrect
Data Record
Check proper operation in the user manual
Black
Display
Temperature is too hot or display exposed to direct sunlight too
long
Display
Readout Fades
Poor battery contacts or dead battery
Display
Shows Irregular
Take out battery and install again
Figures
VIII. STOPWATCH
Ø
Press button D to enter Stopwatch mode.
Ø
Before using the stopwatch, be sure to reset all digits to zero first,
“0:00’00’00”. When the stopwatch is stopped, press button B to
reset. When the stopwatch is counting, press button A to stop the
measurement and then press button B to reset.
Ø
Press
button A to start or stop the measurement.
Ø
Press button B to record a lap or split when the stopwatch is counting.
Ø
REFERENCE:
·
STANDARD MEASUREMENT: A-A-B
START-STOP-RESET
·
ACCUMULATED
ELAPSED TIME MEASUREMENT:
A-A-A-A-B
START-STOP-RESTART-STOP-RESET
·
SPLIT
TIME/LAP TIME MEASUREMENT:
A-B-B-A-B
START-SPLIT LAP 1-SPLIT LAP 2-STOP-RESET
-
“Split time” refers to an elapsed time required to cover a distance
from the start to a given point
-
“Lap
time” refers to an elapsed time required to cover a given section of the
whole distance
·
RECALL LAP/SPLIT MEMORY:
C-A-A-A-C-B
RECALL FASTEST LAP-RECALL LAST SPLIT/LAP-RECALL FIRST
SPLIT/LAP-RECALL SECOND SPLIT/LAP-RETURN TO NORMAL MODE-RESET
IX. DUAL TIMER
Ø
Press
button D to enter Dual Timer mode.
Ø
Hold
button C until the hour digits are flashing to enter timer setting mode.
Ø
Press button B to adjust the flashing digit and then press button A to
confirm.
Ø
Right after the confirmation, minutes digits will then start to flicker.
Press button B again to adjust and button C. Repeat the above process to
set the correct time and press button C to confirm.
Ø
Press button A to start/stop and B to reset
Ø
A beeping alert sound will be turned on at the last 3 seconds and then an
alarm will sound when the timer is up. Simultaneously, the timer cycle
counter will increment by 1 for every completion of the count down.
Ø
SINGLE TIMER COUNTING: A-A-B
-
To
have single timer counting, just set Timer 1 and let Timer 2 be zero,
press button A to start/stop and then B to reset.
Ø
DUAL
TIMER COUNTING:
A-A-B
-
To
have dual timer counting, set both Timer 1 and Timer 2, press button A to
start/stop and then B to reset. For an example of a boxing match, you can
set Timer 1 with 3 minutes and Timer 2 with 1 minute for an interval.
X. STROKE FREQUENCY COUNTER
Ø
Press
button D to enter Stroke Counter mode.
Ø
Press
button A to start and A again to stop after the third stroke was made. The
number of strokes per minute will then be displayed.
Ø
Press
button B to reset.
Ø
The
measurable number of strokes per minute is between 10 and 180.
Ø
“Err” will be displayed when there is an error of out of range
measurement.
|